Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Chim Acta ; 475: 97-101, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28964834

RESUMO

INTRODUCTION: Serum gamma glutamyl transferase (GGT), produced and released mostly from the liver and bile duct, is an enzyme involved in response to oxidative stress, and has been used as a maker for prediction of cardiovascular events. Umbilical artery blood flow resistance index, e.g., the systolic/diastolic ratio (S/D ratio) as determined by ultrasound, has been used to assess the fetal intrauterine conditions. While changes of GGT and S/D ratio in preeclampsia are found to be associated with the risk for adverse perinatal outcome, the potential value of combined use of the two measurements for the prediction of adverse perinatal outcome has not been determined. MATERIALS AND METHODS: This study included severe preeclampsia patients in late pregnancy and determined their serum GGT levels and ultrasonic flow resistance index of umbilical artery within a week before delivery. Demographic data and perinatal outcomes including perinatal death, five-minute Apgar score, admission to neonatal intensive care unit, respiratory distress syndrome, and intrauterine growth restriction, are documented and analyzed. RESULTS: It was found that serum GGT combined with umbilical artery S/D ratio predicted perinatal adverse outcomes in severe preeclampsia patients with a sensitivity of 94.30% and a specificity of 80.00%. Moreover, absent or reversed UA diastolic blood flow was found to be an independent risk factor for intrauterine growth restriction. CONCLUSION: GGT in combination with umbilical artery S/D ratio is a potentially useful marker for the prediction of adverse outcome in severe preeclampsia patients. Future studies in a larger cohort of patients should be performed to verify the efficacy of the strategy. Early and accurate prediction of adverse perinatal events can facilitate the efforts to improve the perinatal outcomes of neonates associated with preeclamptic pregnancies.


Assuntos
Retardo do Crescimento Fetal/diagnóstico , Unidades de Terapia Intensiva Neonatal/estatística & dados numéricos , Pré-Eclâmpsia/diagnóstico por imagem , Síndrome do Desconforto Respiratório do Recém-Nascido/diagnóstico , Artérias Umbilicais/diagnóstico por imagem , gama-Glutamiltransferase/sangue , Adulto , Índice de Apgar , Biomarcadores/sangue , Velocidade do Fluxo Sanguíneo , Diástole , Feminino , Retardo do Crescimento Fetal/fisiopatologia , Feto , Idade Gestacional , Humanos , Recém-Nascido , Parto/fisiologia , Morte Perinatal/etiologia , Pré-Eclâmpsia/sangue , Gravidez , Síndrome do Desconforto Respiratório do Recém-Nascido/fisiopatologia , Índice de Gravidade de Doença , Sístole , Ultrassonografia , Artérias Umbilicais/enzimologia
2.
Sensors (Basel) ; 14(12): 22274-84, 2014 Nov 25.
Artigo em Inglês | MEDLINE | ID: mdl-25429411

RESUMO

A glassy carbon electrode was modified with a copper(II) complex [Cu(Sal-ß-Ala) (3,5-DMPz)2] (Sal = salicylaldehyde, ß-Ala = ß-alanine, 3,5-DMPz = 3,5-dimethylpyrazole) and single-walled carbon nanotubes (SWCNTs). The modified electrode was used to detect catechol (CT) and hydroquinone (HQ) and exhibited good electrocatalytic activities toward the oxidation of CT and HQ. The peak currents were linear with the CT and HQ concentrations over the range of 5-215 µmol·L(-1) and 5-370 µmol·L(-1) with corresponding detection limits of 3.5 µmol·L(-1) and 1.46 µmol·L(-1) (S/N = 3) respectively. Moreover, the modified electrode exhibited good sensitivity, stability and reproducibility for the determination of CT and HQ, indicating the promising applications of the modified electrode in real sample analysis.


Assuntos
Catecóis/análise , Condutometria/instrumentação , Eletrodos , Hidroquinonas/análise , Nanotubos de Carbono/química , Poluentes Químicos da Água/análise , Catecóis/química , Misturas Complexas/análise , Monitoramento Ambiental/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Hidroquinonas/química , Poluentes Químicos da Água/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...